A pool cage is a tall, clear-span aluminum structure that spans an entire pool deck, carries heavy wind uplift on its mansard or hip screen roof, and often serves as the pool's legal safety barrier. In Lake County, where hilltop and lakefront lots can shift the wind exposure, that engineering has to be site-specific. We prepare the signed and sealed pool enclosure package the county requires across Clermont, Leesburg, Tavares and Minneola, and submit it for you.
A pool enclosure is the most demanding aluminum structure we engineer — it spans wide and stands tall over the pool and deck, so its mansard, hip or gable screen roof and the super-gutter tie back to the house have to be sized for real wind, not a catalog detail. Lake County adds a wrinkle a pool cage feels more than a small screen room does: between the elevation around Clermont and Minneola and the hundreds of lakes that give the county its name, exposure category can vary lot to lot. That's a driver of the loads on a tall cage, and we account for it on every project — whether you're caging a pool in a Clermont golf community, a Leesburg neighborhood, or a Tavares lakefront.

Lake County's building division reviews a pool cage as a structure — which means signed, sealed, site-specific engineering, not a manufacturer's generic detail sheet.
Drawings and wind-load calculations must be prepared for your specific cage and sealed by a Florida PE. Reviewers verify that the column sizes, beam spans, roof frame and anchors were sized from the actual calculated pressures for your address.
Lake County and its cities accept applications through their online permitting portals; jurisdictions that still process paper typically want two signed and sealed sets. We prepare the format your reviewing office needs and file the application for you.
Design wind speed is typically around 139 mph (Vult), confirmed per site during design. Because a pool cage stands well above deck level, its exposure category deserves particular attention here — the county's hills and open lakefronts can push it into a category that multiplies the design pressures.
Where the cage acts as the pool's safety barrier, its walls, screen and self-latching access door must meet Florida's residential pool barrier rules. The package also ties the columns into the pool deck or new footings — the base connection that resists the roof's uplift.
Our pool enclosure package starts at $2,000 and includes engineering, wind-load calculations, the PE seal, and submission to Lake County or your municipal building department. Revisions are free until your permit is approved.
| Service | Flat Rate |
|---|---|
| Pool Enclosure (Pool Cage over Pool) | From $2,000 |
| Screen Enclosure / Screen Room (No Pool) | $1,500 |
| Lanai Enclosure | $1,200 |
| Covered Patio | $1,200 |
| Pergola | $1,000 |
| Outdoor Kitchen | $900 |
| Concrete Slab | $900 |
| Pool Demolition | $800 |
| After-the-Fact Permit (Unpermitted Structure) | from $1,500 |
Everything we need to engineer your cage is on your property survey and in a few photos of the pool, deck and house wall: the deck footprint, where columns land, and where the super-gutter ties into the fascia. That's how a Leesburg homeowner and a Clermont pool contractor get the same fast turnaround without waiting on anyone's schedule.
Address, cage dimensions and roof style, pool/deck survey and photos
Flat-rate PDF proposal with scope, price and timeline
Site-specific pool cage design per FBC 2023 / ASCE 7-22 in 5–7 business days
Filed with Lake County or your city · revisions free until approved
Lake County sits just up the road from our Central Florida base, and its mix of hills, lakefronts and fast-growing communities like Minneola makes careful, site-specific engineering matter more than usual — especially on a tall pool cage. Our clients here value one thing above all: cage packages that clear review without drama.
We evaluate exposure for every Lake County lot instead of defaulting to the mildest assumption. On a wide, tall cage that's the difference between a design a reviewer questions and one that sails through — and between an enclosure that holds and one that doesn't.
Clear-span mansard and hip roofs, tall corner columns, super-gutter tie-ins and screen-wall barriers are our routine work. We size the frame and every connection from the actual calculated loads for your Clermont, Leesburg or Tavares lot.
Flat rate quoted the same day, sealed package in 5–7 business days, county submission included, revisions free until approval. Pool contractors can schedule the screen crew with confidence.

The sealed engineering package takes 5–7 business days. County review of residential accessory structures typically runs a few weeks depending on workload. We submit for you and handle reviewer comments free until approval.
Typically around 139 mph (Vult) per ASCE 7-22, confirmed per site during design. Because a cage is tall and clear-span, its exposure category is a bigger factor here — the county's hills and open lakefronts can raise the design pressures.
It can — but only when permitted, inspected and detailed for it. Florida's residential pool barrier rules set requirements for the screen walls, gaps and a self-closing, self-latching access door. An unpermitted cage does not legally qualify. We can prepare the drawings so the enclosure is documented as the barrier.
It can. An open lot facing a lake near Tavares or Leesburg, or a Clermont or Minneola hilltop, may carry a more severe exposure category than a shielded lot — increasing loads on the columns, beams and anchors of a tall cage. Confirmed per site during design.
Yes — unincorporated Lake County plus all municipal building departments, including Clermont, Leesburg, Tavares and Minneola. We file with whichever jurisdiction reviews your address, and the whole process is handled remotely.
Screening a deck without a pool, or adding a plain screen room? See our Lake County screen enclosure permit page.
Send your survey and photos — get a same-day flat-rate proposal and a PE-sealed, submission-ready pool enclosure package in 5–7 business days.